论文已发表
注册即可获取德孚的最新动态
IF 收录期刊
BacT/ALERT FAN Plus 和 BACTEC 有氧和无氧培养基在模拟血液培养中灭活临床常用抗菌剂:在中国大陆的首次比较评估
Authors Xu X, Wei Q, Wang Z, Yan J, Wang H, Xia Y
Received 3 November 2020
Accepted for publication 22 December 2020
Published 19 January 2021 Volume 2021:14 Pages 163—172
DOI https://doi.org/10.2147/IDR.S290222
Checked for plagiarism Yes
Review by Single anonymous peer review
Peer reviewer comments 2
Editor who approved publication: Dr Héctor M. Mora-Montes
Purpose: To evaluate the antimicrobial inactivation capabilities of BacT/ALERT (FA Plus and FN Plus) and BACTEC (Plus Aerobic/F and Lytic/10 Anaerobic/F) media.
Patients and Methods: The inactivation capabilities of the commercial blood culture media were compared using 21 microorganism-antimicrobial combinations in simulated adult blood cultures.
Results: BacT/ALERT culture media demonstrated higher detection rates than the BACTEC culture media. The recovery rates of the aerobic bottles were 74/115 (64.3%) for FA Plus bottles and 64/115 (55.7%) for BACTEC Aerobic Plus bottles. The BacT/ALERT FAN Plus culture media exhibited a shorter time to detection (TTD). The TTD of FA Plus media was 14.7 h, 4.85 h shorter than the BACTEC Aerobic media (19.55 h), while the TTDs of FN Plus media and BACTEC Anaerobic media were 16.8 h and 18.4 h, respectively.
Conclusion: BacT/ALERT (FA Plus and FN Plus) media showed relative, but not absolute, advantages, as it had higher detection rates and shorter TTD and thus can be selectively applied to patients with prior use of antimicrobial agents before blood culture samples are taken.
Keywords: antimicrobial inactivation, blood culture, automated system, BacT/ALERT FAN plus media, comparative evaluation