EDTA-K2 通过在免疫色谱分析中螯合胶体金提高了 SARS-CoV-2 IgM 和 IgG 抗体的检测灵敏度
Authors Hu X, Wu C, Situ B, Tian P, An T, Li Q, Pan W, Zhang R, Yang B, Sun D, Hu Y, Wang Q, Zheng L
Received 17 September 2020
Accepted for publication 24 December 2020
Published 29 January 2021 Volume 2021:16 Pages 715—724
DOI https://doi.org/10.2147/IJN.S281594
Checked for plagiarism Yes
Review by Single anonymous peer review
Peer reviewer comments 3
Editor who approved publication: Dr Farooq A. Shiekh
Objective: The coronavirus disease (COVID-19) pandemic, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is now rapidly spreading globally. Serological tests are an important method to assist in the diagnosis of COVID-19, used for epidemiological investigations. In this study, we aimed to investigate the impact of different types of vacuum collection tubes on the detection of SARS-CoV-2 IgM and IgG antibodies, using the colloidal gold immunochromatographic assay (GICA).
Patients and Methods: A total of 112 patients with COVID-19 and 200 healthy control subjects with no infection were enrolled in this study. Their serum and plasma were collected into four different types of vacuum blood collection tubes. SARS-CoV-2 IgM and IgG specific antibodies in the plasma and serum were then detected by GICA and chemiluminescence assay (CA), respectively. In addition, the particle sizes of different colloidal gold solutions in the presence of different anticoagulants and coagulants were evaluated by both laser diffraction (Malvern) and confocal laser microscope, respectively.
Results: Our results revealed that anticoagulated plasma with EDTA-K2 improved the positive detection rate of SARS-CoV-2 IgM antibodies. Furthermore, our results shown that the detection results by GICA and CA were highly consistent, especially, the results of EDTA-K2 anticoagulated plasma detected by GICA was more consistent with CA results. We confirmed that EDTA-K2 could improve the detection sensitivity of SARS-CoV-2 IgG antibodies by chelating excessive colloidal gold compared with sodium citrate or lithium heparin, these methodologies did not appear to cause false positives. Colloidal gold particles could be chelated and aggregated by EDTA-K2, but not by sodium citrate, lithium heparin and coagulants.
Conclusion: GICA is widely used to detect antibodies for the advantages of convenient, fast, low cost, suitable for screening large sample and require minimal equipment. In this study, we found that EDTA-K2 amplified the positive antibody signal by chelating colloidal gold and improved the detection sensitivity of SARS-CoV-2 IgM and IgG antibodies when using the GICA. Therefore, we suggested that EDTA-K2 anticoagulated plasma was more suitable for the detection of SARS-CoV-2 antibodies.
Keywords: EDTA-K2, SARS-CoV-2, antibodies, gold immunochromatographic assay; GICA