论文已发表
注册即可获取德孚的最新动态
IF 收录期刊
左心耳的影像学评估:CT 大螺距动脉期延迟扫描
Authors An P , Tian Q, Duan S, Feng X, Han Y, Wei Y, Wang W , Yin Q
Received 4 June 2025
Accepted for publication 25 August 2025
Published 1 September 2025 Volume 2025:18 Pages 4965—4973
DOI https://doi.org/10.2147/IJGM.S537696
Checked for plagiarism Yes
Review by Single anonymous peer review
Peer reviewer comments 2
Editor who approved publication: Dr Redoy Ranjan
Pan An, Qiang Tian, Shijun Duan, Xiulong Feng, Yu Han, Yaoning Wei, Wen Wang, Qian Yin
Department of Radiology, Tangdu Hospital, The Fourth Military Medical University, Xi’an, Shaanxi Province, 710038, People’s Republic of China
Correspondence: Qian Yin, Department of Radiology, Tangdu Hospital, The Fourth Military Medical University, Xi’an, Shaanxi Province, 710038, People’s Republic of China, Tel +86 15991988381, Email cissia@163.com Wen Wang, Department of Radiology, Tangdu Hospital, The Fourth Military Medical University, Xi’an, Shaanxi Province, 710038, People’s Republic of China, Email wangwen@fmmu.edu.cn
Purpose: Compared with retrospective ECG-gated arterial phase scan, to investigate the clinical application value of dual-source CT large-spiral arterial late scan in the imaging evaluation of left atrial appendage (LAA).
Patients and Methods: A total of 108 patients requiring LAA CT angiography (CTA) due to atrial fibrillation (AF) were selected from September 2024 to December 2024, including 52 patients in group A (Flash large-spiral arterial late scan) and 56 patients in group B (retrospective ECG-gated arterial phase scan). All patients underwent double-phase scan. The interval between the two periods is 30s. Clinical data of patients were collected, the scanning range and radiation dose received were recorded. The CT values of LAA, ascending aorta (AA) at the same level and left atrium at the largest level were measured. At the same time, evaluate other meaningful lesions within the scan range.
Results: The difference between the two groups of scanning range and radiation dose was statistically significant (P < 0.05). There was statistical significance in the subjective evaluation and objective evaluation of LAA filling at the first phase scanning of the two groups (P < 0.05). The detection of other meaningful lesions in the scanning range of group A was significantly higher than that of group B.
Conclusion: By adopting the three-generation dual-source FLASH large-pitch arterial late scan mode, the complete filling rate of the LAA was significantly improved. Not only shortened the examination time, reduced the radiation dose, but also increased the detection rate of other significant lesions within the scanning range for the patients.
Keywords: atrial fibrillation, atrial appendage, tomography, X-ray computed, radiation dose, transesophageal echocardiography