身体两侧血培养好氧/厌氧瓶采集模式对血培养阳性率和阳性时间的影响
Authors Wen H, Wang W, Xie S, Sun Q, Liang Y, Wen B, Liu Y, Sun L, Zhang Z , Cao J, Liu X, Niu X, Ouyang Z, Dong N, Zhao J
Received 10 February 2022
Accepted for publication 27 May 2022
Published 10 June 2022 Volume 2022:15 Pages 2995—3004
DOI https://doi.org/10.2147/IDR.S358675
Checked for plagiarism Yes
Review by Single anonymous peer review
Peer reviewer comments 3
Editor who approved publication: Professor Suresh Antony
Background: Although the principles for blood cultures (BCs) guidelines provide a recommendation for collection patterns, the complexity of clinical practice occasionally prompts clinicians to adopt non-standard collection patterns. Here, we investigate the influences of different BC collection patterns on detection of pathogens.
Methods: The BC collection patterns of 96 hospitals were surveyed online. And a retrospective study of BC data from a tertiary hospital was conducted.
Results: The results showed that 53.1% of hospitals adopted the recommended patterns. Among the 1439 episodes of true-positive BCs, 67.4% were found in both the left- and right-sided bottles; 58.2% were found in both aerobic and anaerobic bottles.
Conclusion: The present study suggested that the rate of standard collection patterns of blood culture was low and the non-standard collection patterns were associated with decreased detection of pathogens. Simultaneous collection of blood on the left and right sides was recommended as an effective pattern of BC collection.
Keywords: blood culture, collection pattern, online survey, time-to-positivity, pathogen detection