已发表论文

静脉治疗中的用药安全:在模拟y部位给药过程中依托泊苷与肿瘤重症监护中常用药物的相容性

 

Authors Ding H , Tong T, Liu S , Tang L, Chen Z

Received 11 September 2024

Accepted for publication 13 February 2025

Published 18 February 2025 Volume 2025:19 Pages 1147—1161

DOI https://doi.org/10.2147/DDDT.S489534

Checked for plagiarism Yes

Review by Single anonymous peer review

Peer reviewer comments 2

Editor who approved publication: Prof. Dr. Georgios Panos

Haiwen Ding,1– 3 Tong Tong,1– 3 Sheng Liu,1– 3 Liqin Tang,1– 3 Zhaolin Chen1– 3 

1Department of Pharmacy, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, People’s Republic of China; 2Anhui Provincial Key Laboratory of Precision Pharmaceutical Preparations and Clinical Pharmacy, Hefei, Anhui, People’s Republic of China; 3Department of pharmacy, Centre for Leading Medicine and Advanced Technologies of IHM, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, People’s Republic of China

Correspondence: Zhaolin Chen; Liqin Tang, Department of Pharmacy, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230001, People’s Republic of China, Tel/Fax +86 551 62283378, Email czl0808@ustc.deu.cn; tangliqin@ustc.deu.cn

Objective: Etoposide is an antineoplastic agent widely used to treat pediatric and adult cancers. Critically ill patients are expected to receive several intravenous pharmaceutical drugs while admitted to hospitals. When compatibility data are available, intravenous drugs may be administered simultaneously through the Y-site. This study aimed to determine the compatibility of etoposide during simulated Y-site administration with 45 continuous-infusion drugs that are commonly administered in tumor critical care units.
Methods: Etoposide was diluted to a concentration of 0.25 mg/mL in 0.9% sodium chloride (NS) and other intravenously tested drugs were reconstituted according to the manufacturer’s recommendations to the final clinical desired concentrations. Y-site administration was simulated in vitro by mixing 5 mL etoposide with other diluted intravenous medications under aseptic conditions in a 1:1 ratio. Compatible solutions were withdrawn at certain time intervals (0, 1, 2, 4 hours) after mixing and tested visually, using a Tyndall beam, pH, turbidity, insoluble particles, and UV absorption as measures of compatibility.
Results: Etoposide was compatible with 38 (84%) of the 45 drugs tested within four hours. Glutathione and human granulocyte colony-stimulating factor immediately showed incompatibility with etoposide. Within 1 h, four medications (cefuroxime sodium, ilaprazole sodium, mycophenolate, and xuebijing) were incompatible. Within 4 h, one medications (ceftazidime) were also found to be incompatible with etoposide under observation.
Conclusion: Seven of the 45 common medications in tumor critical care tested with etoposide were incompatible within 4 h. If co administration is inevitable and the drug is infused through a port catheter, a larger volume of saline (NS) or dextrose 5% in water (D5W) should be used to flush the port catheter before and after the etoposide infusion to clean the lumen of the port catheter.

Keywords: compatibility, Y-site administration, intravenous, etoposide, critical care